Photo 1

Wiper WAT 125x140x9,5 C0

CodeWAT 1250 1400 095 C0
AvailabilityOn request
Wiper WAT 125x140x9,5 C0—

Technical data

Properties
Seal typeWAT
Material typePU
Foreign code2EWAT362
BrandArtic seals
Weight64g
Wipers dimension
Inside diameter d125mm
Outside diameter D140mm
Width h9,5mm
Width H13mm

Documents

Material

PU / TPU / H-PU (polyurethane)

  • Standard PU / TPU-30 °C to +80 °C

Best for high pressure and abrasion, in mineral hydraulic oil. Standard PU must never meet hot water, steam or brake fluid, or run hotter than +90 °C.

Chemical resistance
Can be usedDo not use
Extreme pressure and pulsation (up to 40-50 MPa, very resistant to extrusion into the gap)Hot water and steam with standard PU: hydrolysis, it breaks down into powder
Abrasion, friction, cutting and tearing (4-5 times tougher than NBR)Glycol brake fluid (DOT 3, DOT 4, DOT 5.1): swells quickly
Mineral hydraulic oil (HL, HLP) and greaseHigh temperatures above +90 to +100 °C with standard TPU: it softens
Fuel oil, diesel and technical oils (aliphatic hydrocarbons)Strong (concentrated) acids and alkalis: sulfuric, nitric, caustic soda
Ozone, weather and sunlight (does not crack from weather)Acetone, MEK, toluene, benzene, dichloromethane (polar and aromatic solvents)
Water-based fire-resistant fluids HFA, HFB (only special H-PU)Synthetic ester oils and fire-resistant fluid HFD-R
Dry compressed air and technical gasesStrong alcohols (methanol, ethanol): swelling

Water and heat destroy standard PU: above +50 to +60 °C in water or damp oil it turns into a sticky paste or crumbles. If the system contains water or an emulsion, use only H-PU (hydrolysis-resistant).

We recommend: Industrial chemicals